INSTALLER GUIDE
We trust that these instructions give sufficient details to enable this appliance to be
installed and maintained satisfactorily. However, if further information is required, our
Technical Helpline will be pleased to help.
Telephone 08706 061 065 (National call rates apply in the United Kingdom)
In the Republic of Ireland call 0044 8706 061 065
Manufactured by Morsø Jernstøberi A/S, Furvej 6, 7900 Nykøbing Mors, Denmark
Distributed by Baxi Fires Division, Wood Lane, Erdington, Birmingham B24 9QP,
England
INSTALLER: Please leave this guide with the
owner
THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20)
WHEN CONVERTED USING CONVERSION KIT NO. 0555211 THIS
APPLIANCE IS FOR USE WITH PROPANE GAS (G31)
THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED
KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE).
morsø
SQUIRREL
BALANCED FLUE
GAS STOVE
MODEL No. 552
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - GAS STOVE

600B475/03INSTALLER GUIDEWe trust that these instructions give sufficient details to enable this appliance to beinstalled and maintained satisfactoril

Page 2

! Timber frame buildings:Fit a drip collar round the flue positioned so that it willbe located in the centre of the wall cavity - see figure 6. The dr

Page 3

4. PACK CONTENTSPack 11 Cast iron stove containing gas burner unit & interior flueway2 Ceramic base pieces1 Set of 7 coals1 Pair of ceramic fireb

Page 4

6. IGNITION CHECKBefore attempting to install, it is worth checking that the ignition system performssatisfactorily.See figure 12.Set the right hand c

Page 5

firebox plate. Push down to hold the ceramicside wall in place.6. Fit the right hand side wall against the righthand side of the firebox. Locate the b

Page 6

There are seven overlay coals. There are threeceramic coals identified with the number’1’.Two identified with the number ‘2’ and twoidentified with th

Page 7

8. FINAL CHECKS8.1 Checking the full operating sequence.See figure 12.If the fire is turned off or the flames go out, waitat least 3 minutes before at

Page 8

8.2 Checking the reference pressure.The burner aeration is non-adjustable. Theappliance is preset to give the correct heatinput on Natural Gas at 20 m

Page 9

vapours may be given off which may cause a slight odour and could possibly set off anysmoke alarms in the immediate vicinity. These vapours are quite

Page 10 - INSTALLER GUIDE

LIST OF CONTENTSSection Heading Page1. SAFETY 22. APPLIANCE DATA 33. GENERAL INSTALLATION REQUIREMENTS 44. STOVE LOCATION 84.1 Preparing t

Page 11

2. APPLIANCE DATAThis product uses fuel effect pieces and burner compartment walls containingRefractory Ceramic Fibres (RCF), which are man-made vitre

Page 12

3. GENERAL INSTALLATION REQUIREMENTS3.1 The installation must be in accordance with these instructions.For the user’s protection, in the United Kingdo

Page 13

The outside wall thickness must meet the conditions shown in figure 1.The flue terminal position must meet the conditions shown in figure 2.The flue d

Page 14

*In addition, the terminal should not be nearer than 300mm to an opening in thebuilding fabric formed for the purpose of accommodating a built-in elem

Page 15

Ventilation: In the United Kingdom (GB) no special ventilation bricks or vents arerequired in the room containing this appliance.In the Republic of Ir

Page 16

Soft wall coverings (e.g. embossed vinyl etc.) are easily affected by heat. They maytherefore, scorch or become discoloured when close to a heating a

Page 17

leaf is shown in figure 3.!Fit the non-combustible sleeve to the inner leaf. The sleeve must extend to be atleast flush with thebreather membrane /tim